Public COA audit

BPC-157 · TB-500

Audited July 28, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
72
Confidence
83%
Panels
3/7
Purity (printed)
99.56%

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
BPTB20-052026-7
Identity method
LC-MS
Sample date
2026-05-12
Issue date
2026-05-14

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

3 of 7 present · 3 passed · 0 failed · 0 reported · 4 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    BPC-157/Thymosin Beta-4 confirmed

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    99.56%

  • Heavy metals

    Not on this COA

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

  • Microbial

    Not on this COA

    Bioburden / microbial limits testing.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

  • Endotoxin

    Tested · passed · core

    LAL or chromogenic endotoxin assay.

    Replicate 1: Pass, Replicate 2: Pass, Sensitivity ≤0.05 EU/mL

  • Sterility

    Not on this COA

    Sterility testing where applicable.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

  • Residual solvent / water

    Not on this COA

    Residual solvents or water content limits.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing

Not on this certificate. Lowers thoroughness; you decide if that panel matters for your use case. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High purity confirmed

    99.56% purity by HPLC-UV is within normal range for research peptides

  • Identity confirmed by LC-MS

    Both BPC-157 and Thymosin Beta-4 identified with mass spectrometry confirmation shown

  • Batch/lot number present

    Lot BPTB20-052026-7 clearly stated with search code Whol2605120091

  • Dates within normal range

    Received 2026-05-12, Reported 2026-05-14 (2-day turnaround is reasonable)

  • Lab verification unclear

    Freedom Diagnostics Testing website and contact provided, but independent verification of lab accreditation/credentials not possible from document alone

  • Limited testing panels

    Only identity, purity, and endotoxin panels present. Missing heavy metals, microbial, sterility, and residual solvent/water testing

  • Endotoxin testing performed

    USP <85> compliant LAL assay with duplicate replicates, both passing at ≤0.05 EU/mL sensitivity

  • Professional presentation

    Document includes chromatogram, mass spectrometry data, signature, and appropriate research-use-only disclaimers

  • Net content exceeds label claim

    BPC-157 shows 13.74mg vs 10mg label (37% overfill), TB-500 shows 13.27mg vs 10mg label (33% overfill). While overfill is common practice, this magnitude warrants documentation

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.