Public COA audit

Retatrutide

Audited September 5, 2026

Incomplete documentation

Missing panels or key metadata — not enough evidence to treat this as a full certificate.

Legitimacy
45
Confidence
85%
Panels
1/7

Scored poorly because the file is incomplete or not a full COA, limited panel coverage (1/7), 3 critical findings, and notable note: "Heavy metals only report". To improve: upload the full certificate (or the matching sibling purity/endotoxin report) and include identity, purity, and endotoxin at minimum.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
RT202603
Issue date
2026-04-03

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

1 of 7 present · 1 passed · 0 failed · 0 reported · 6 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Not on this certificate file · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Purity

    Not on this certificate file · core

    Reported purity percentage for the analyte.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Heavy metals

    Tested · passed

    Lead, arsenic, cadmium, mercury, or similar limits.

    All ICH Class 1-3 metals below limits; Barium 0.348 µg detected

  • Microbial

    Not on this certificate file

    Bioburden / microbial limits testing.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Endotoxin

    Not on this certificate file · core

    LAL or chromogenic endotoxin assay.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Sterility

    Not on this certificate file

    Sterility testing where applicable.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • Heavy metals only report

    This COA contains ONLY heavy metals testing (EPA 208/245 methods). No identity confirmation (MS, NMR, HPLC), no purity analysis, no endotoxin, no microbial, no sterility testing. This is a partial/scoped report for heavy metals analysis only.

  • No purity data

    No HPLC, LC-MS, or other purity percentage reported. Cannot assess compound purity from this document.

  • No identity confirmation

    No mass spectrometry, NMR, or other identity confirmation method present. Cannot verify the sample is actually Retatrutide.

  • No sample/receipt date

    Document shows publication date 2026-04-03 but no sample receipt or analysis date. Cannot assess testing timeline.

  • Lab information present

    TrustPointe Analytics LLC with full address (Dorr, MI), phone, email, website, and verification URL with key G5EDRFAH34GE provided.

  • Comprehensive heavy metals panel

    Extensive ICH Q3D-compliant heavy metals testing covering Class 1 (As, Cd, Pb, Hg), Class 2a (Co, Ni, V), Class 2b (Se, Ag, Tl), and Class 3 (Sb, Ba, Cr, Cu, Mo) elements plus additional elemental analysis. All results within acceptable limits.

  • Professional formatting

    Clean layout with QR code verification, dual signatures (President and Managing Director), proper header/footer with contact information across both pages.

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.