Public COA audit
Tirzepatide
Audited July 29, 2026
Several fields check out, but we found issues worth reviewing before you rely on this document.
- Legitimacy
- 92
- Confidence
- 88%
- Panels
- 2/7
- Purity (printed)
- 99.9%
Document details
Fields extracted from the certificate — not order or payment data.
- Batch / lot
- x5qmv2y
- Identity method
- HPLC-UV-MS
- Sample date
- 2026-06-09
- Issue date
- 2026-06-16
7-panel checklist
Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.
2 of 7 present · 2 passed · 0 failed · 0 reported · 5 missing
Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.
Identity
Tested · passed · core
Compound identity confirmed (e.g. HPLC, mass spec).
ID Confirmed
Purity
Tested · passed · core
Reported purity percentage for the analyte.
>99.9%
Heavy metals
Not on this COA
Lead, arsenic, cadmium, mercury, or similar limits.
No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.
Microbial
Not on this COA
Bioburden / microbial limits testing.
No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.
Endotoxin
Not on this COA · core
LAL or chromogenic endotoxin assay.
No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.
Sterility
Not on this COA
Sterility testing where applicable.
No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.
Residual solvent / water
Not on this COA
Residual solvents or water content limits.
No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.
How to read this
Had data · good
Panel present with a pass (or clear acceptance).
Had data · bad
Panel present with a fail — a concrete quality signal.
Had data · unclear
Value reported without an explicit pass/fail mark.
Missing
Not on this certificate. Lowers thoroughness; you decide if that panel matters for your use case. PeptIQ’s score still factors coverage.
Findings
Evidence-linked observations from this audit.
Dates are reasonable and consistent
Sample received 2026-06-09, tested 2026-06-11, report issued 2026-06-16. All dates are sequential and on or before 2026-07-29 (today).
High chromatographic purity
HPLC purity >99.9% is excellent and typical for research-grade peptides. Chromatogram shows single dominant peak consistent with high purity.
Identity confirmed by mass spectrometry
Mass spectral match confirmed via HPLC-UV-MS. Mass spectrum on page 3 shows expected m/z peaks for Tirzepatide including 1613.1 (base peak) consistent with multiply-charged peptide ions.
Batch/lot number present
Batch x5qmv2y clearly labeled on vial images and throughout document.
Testing lab identified
Krause Analytical LLC, 8127 Mesa Drive Suite B-206, Austin, TX 78759. Lab director Mark C. Krause signature present. Verification URL provided: https://finnrick.com/verify
Limited testing panels
Only identity and purity panels performed. Methods for endotoxin and heavy metals are described on page 4 but no results are shown. Microbial, sterility, and residual solvent testing not performed. This is not uncommon for basic peptide analysis but limits comprehensive quality assessment.
Professional presentation
Document includes detailed chromatogram (page 2), mass spectrum (page 3), and methods summary (page 4). Formatting is consistent with professional analytical lab reports. Watermark present throughout.
Dual branding requires clarification
Document shows both 'Finnrick Analytics' and 'Krause Analytical LLC' branding. Header says 'Finnrick Testing Certificate' but footer and signature reference Krause Analytical. This may indicate a vendor/lab relationship but creates minor ambiguity about the actual testing entity.
PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.