Public COA audit
Tesamorelin
Audited July 29, 2026
Several fields check out, but we found issues worth reviewing before you rely on this document.
- Legitimacy
- 92
- Confidence
- 93%
- Panels
- 2/7
- Purity (printed)
- 99.6%
Document details
Fields extracted from the certificate — not order or payment data.
- Batch / lot
- WL-TSM10-P00520
- Identity method
- FTIR (USP <197A>)
- Sample date
- 2026-06-08
- Issue date
- 2026-06-12
7-panel checklist
Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.
2 of 7 present · 2 passed · 0 failed · 0 reported · 5 missing
Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.
Identity
Tested · passed · core
Compound identity confirmed (e.g. HPLC, mass spec).
FTIR sample spectrum confirms the presence of Tesamorelin with addition of excipient(s)/fillers
Purity
Tested · passed · core
Reported purity percentage for the analyte.
99.6%
Heavy metals
Not on this COA
Lead, arsenic, cadmium, mercury, or similar limits.
No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.
Microbial
Not on this COA
Bioburden / microbial limits testing.
No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.
Endotoxin
Not on this COA · core
LAL or chromogenic endotoxin assay.
No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.
Sterility
Not on this COA
Sterility testing where applicable.
No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.
Residual solvent / water
Not on this COA
Residual solvents or water content limits.
No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.
How to read this
Had data · good
Panel present with a pass (or clear acceptance).
Had data · bad
Panel present with a fail — a concrete quality signal.
Had data · unclear
Value reported without an explicit pass/fail mark.
Missing
Not on this certificate. Lowers thoroughness; you decide if that panel matters for your use case. PeptIQ’s score still factors coverage.
Findings
Evidence-linked observations from this audit.
High HPLC purity confirmed
99.6% purity by HPLC (USP <621>) meets specification of ≥98%. This is normal for research-grade peptides.
Identity confirmed by FTIR
FTIR spectrum confirms Tesamorelin presence with excipients/fillers, consistent with formulated peptide product.
Batch information complete
Lot number WL-TSM10-P00520, BT Sample ID 005000040403815, labeled potency 10 mg, actual potency 11 mg (110.4%).
Dates are consistent and current
Date tested: 2026-06-08, Issue date: 2026-06-12. Both dates are reasonable and within normal turnaround time.
Lab information provided
BTLabs, West Palm Beach, FL with contact information and website. Document includes QR code and report number IF-824-QSA-TR006-BTL2718-12.
Limited testing scope
Document explicitly states it does not provide information on particulate matter, microbial contamination, or endotoxins. Only identity, purity, and potency testing performed.
Professional presentation
Document includes FTIR spectrum, HPLC chromatogram, signatures of two scientists (Andrea Castro, AS and Verna Zheng, AS), and proper USP method references.
PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.