Public COA audit
TB-500 · Thymosin β4
Audited July 29, 2026
Several fields check out, but we found issues worth reviewing before you rely on this document.
- Legitimacy
- 92
- Confidence
- 88%
- Panels
- 4/7
- Purity (printed)
- 99.91%
Document details
Fields extracted from the certificate — not order or payment data.
- Batch / lot
- 7wdwhn8
- Identity method
- HPLC-UV-MS
- Sample date
- 2025-11-26
- Issue date
- 2025-12-06
7-panel checklist
Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.
4 of 7 present · 2 passed · 0 failed · 2 reported · 3 missing
Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.
Identity
Tested · passed · core
Compound identity confirmed (e.g. HPLC, mass spec).
ID Confirmed
Purity
Tested · passed · core
Reported purity percentage for the analyte.
99.91%
Heavy metals
Tested · result on file
Lead, arsenic, cadmium, mercury, or similar limits.
Microbial
Not on this COA
Bioburden / microbial limits testing.
No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.
Endotoxin
Tested · result on file · core
LAL or chromogenic endotoxin assay.
Sterility
Not on this COA
Sterility testing where applicable.
No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.
Residual solvent / water
Not on this COA
Residual solvents or water content limits.
No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.
How to read this
Had data · good
Panel present with a pass (or clear acceptance).
Had data · bad
Panel present with a fail — a concrete quality signal.
Had data · unclear
Value reported without an explicit pass/fail mark.
Missing
Not on this certificate. Lowers thoroughness; you decide if that panel matters for your use case. PeptIQ’s score still factors coverage.
Findings
Evidence-linked observations from this audit.
High chromatographic purity
99.91% purity by HPLC-UV/MS is excellent and typical for research-grade peptides
Identity confirmed by mass spectrometry
Mass spectrum matches reference standard for Thymosin β4 (CAS 77591-33-4)
Potency exceeds label claim
10.9 mg measured vs 10 mg label claim (109.1% of label)
Batch/lot number present
Lab # 130689, Project 135526, Sample ID 7wdwhn8
Dates are logical and recent
Sample received 2025-11-26, tested 2025-11-28, report issued 2025-12-06
Lab identification present
Krause Analytical LLC, Austin TX, with director signature (Mark C. Krause)
Verification URL provided
https://finnrick.com/verify with certificate ID 7wdwhn8
Supporting chromatogram and mass spectrum included
Page 2 shows clean chromatogram with single major peak at 4.79 min and matching mass spectrum
Endotoxin and metals methods described but results not shown
Page 3 describes USP/NF 85 (endotoxin) and USP/NF 233 (metals) methods, but no numerical results appear on page 1
Watermark overlay throughout document
Large 'FINNRICK' watermark obscures portions of text but does not prevent reading key data
PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.