Public COA audit
HGH · Somatropin
Audited July 29, 2026
Several fields check out, but we found issues worth reviewing before you rely on this document.
- Legitimacy
- 72
- Confidence
- 83%
- Panels
- 2/7
- Purity (printed)
- 94.5%
Document details
Fields extracted from the certificate — not order or payment data.
- Batch / lot
- myej4zx
- Identity method
- HPLC-UV-MS
- Sample date
- 2026-05-30
- Issue date
- 2026-06-04
7-panel checklist
Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.
2 of 7 present · 2 passed · 0 failed · 0 reported · 5 missing
Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.
Identity
Tested · passed · core
Compound identity confirmed (e.g. HPLC, mass spec).
ID Confirmed
Purity
Tested · passed · core
Reported purity percentage for the analyte.
94.5%
Heavy metals
Not on this COA
Lead, arsenic, cadmium, mercury, or similar limits.
No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.
Microbial
Not on this COA
Bioburden / microbial limits testing.
No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.
Endotoxin
Not on this COA · core
LAL or chromogenic endotoxin assay.
No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.
Sterility
Not on this COA
Sterility testing where applicable.
No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.
Residual solvent / water
Not on this COA
Residual solvents or water content limits.
No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.
How to read this
Had data · good
Panel present with a pass (or clear acceptance).
Had data · bad
Panel present with a fail — a concrete quality signal.
Had data · unclear
Value reported without an explicit pass/fail mark.
Missing
Not on this certificate. Lowers thoroughness; you decide if that panel matters for your use case. PeptIQ’s score still factors coverage.
Findings
Evidence-linked observations from this audit.
Chromatographic purity reported
94.5% purity by HPLC-UV/MS, which is within normal range for research peptides
Mass spectral identity confirmed
ID confirmed by HPLC-UV-MS with CAS 12629-01-5 for Somatropin
Dual branding inconsistency
Document shows both 'Finnrick Analytics' and 'Krause Analytical LLC' branding. Header says 'Finnrick.com' and 'Finnrick Analytics', but footer and signature reference 'Krause Analytical LLC' at 8127 Mesa Drive Suite B-206 Austin, TX 78759. This dual branding pattern is unusual and may indicate reseller/white-label arrangement or potential document manipulation
Batch/lot number present
Batch/Lot myej4zx clearly stated with vial photo showing matching label
Date sequence logical
Date received 5/22/2026, sample date 5/30/2026, report issued 6/4/2026 - all dates are sequential and on or before 2026-07-29
Limited testing panels
Only identity and purity panels performed. No heavy metals, microbial, endotoxin, sterility, or residual solvent testing shown on this COA, though methods summary on page 4 references endotoxin and metals procedures
Large watermark overlay
Heavy 'FINNRICK' watermark across all pages may obscure details and is atypical for final issued COAs
Verification URL domain mismatch
Verification URL is https://finnrick.com/verify but lab name is Krause Analytical LLC - suggests third-party reseller or white-label service
PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.