Public COA audit

Ovagen

Audited July 29, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
72
Confidence
85%
Panels
2/7
Purity (printed)
92.861%

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
N/A
Identity method
HPLC with UV Detection Coupled with Mass Spectrometry
Sample date
2026-02-13
Issue date
2026-02-16

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

2 of 7 present · 2 passed · 0 failed · 0 reported · 5 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    Ovagen confirmed by mass spectrometry [M+H]+ 375.93, 857.93

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    92.861%

  • Heavy metals

    Not on this COA

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

  • Microbial

    Not on this COA

    Bioburden / microbial limits testing.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

  • Endotoxin

    Not on this COA · core

    LAL or chromogenic endotoxin assay.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

  • Sterility

    Not on this COA

    Sterility testing where applicable.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

  • Residual solvent / water

    Not on this COA

    Residual solvents or water content limits.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing

Not on this certificate. Lowers thoroughness; you decide if that panel matters for your use case. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • Purity reported at 92.861%

    HPLC purity is within normal range for research peptides. Chromatogram shows clean single peak at ~2.5 minutes.

  • Identity confirmed by mass spectrometry

    Mass spec data shows [M+H]+ ions at 375.93 and 857.93 m/z, consistent with peptide identification.

  • Lot number listed as N/A

    No batch or lot number provided, which reduces traceability for quality control purposes.

  • Dates are reasonable

    Received 2026-02-13, reported 2026-02-16 (3-day turnaround). Both dates are before today (2026-07-29).

  • Lab verification unclear

    Freedom Diagnostics is listed with a searchable URL (FreedomDiagnosticsTesting.com), but independent verification of this lab's accreditation status is recommended.

  • Limited testing scope

    Only identity and purity panels performed. No heavy metals, microbial, endotoxin, sterility, or residual solvent testing. This is common for basic research-grade testing but limits safety assurance.

  • Professional presentation

    Document includes lab logo, chromatogram, mass spectrum, product photo, and chemist signature. Layout appears consistent with legitimate COA formatting.

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.