Public COA audit
KPV
Audited July 29, 2026
Several fields check out, but we found issues worth reviewing before you rely on this document.
- Legitimacy
- 88
- Confidence
- 92%
- Panels
- 2/7
- Purity (printed)
- 96.4%
Document details
Fields extracted from the certificate — not order or payment data.
- Batch / lot
- wgy75q7
- Identity method
- HPLC-UV-MS
- Sample date
- 2026-07-09
- Issue date
- 2026-07-17
7-panel checklist
Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.
2 of 7 present · 2 passed · 0 failed · 0 reported · 5 missing
Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.
Identity
Tested · passed · core
Compound identity confirmed (e.g. HPLC, mass spec).
ID Confirmed
Purity
Tested · passed · core
Reported purity percentage for the analyte.
96.4%
Heavy metals
Not on this COA
Lead, arsenic, cadmium, mercury, or similar limits.
No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.
Microbial
Not on this COA
Bioburden / microbial limits testing.
No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.
Endotoxin
Not on this COA · core
LAL or chromogenic endotoxin assay.
No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.
Sterility
Not on this COA
Sterility testing where applicable.
No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.
Residual solvent / water
Not on this COA
Residual solvents or water content limits.
No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.
How to read this
Had data · good
Panel present with a pass (or clear acceptance).
Had data · bad
Panel present with a fail — a concrete quality signal.
Had data · unclear
Value reported without an explicit pass/fail mark.
Missing
Not on this certificate. Lowers thoroughness; you decide if that panel matters for your use case. PeptIQ’s score still factors coverage.
Findings
Evidence-linked observations from this audit.
HPLC purity confirmed
Chromatographic purity of 96.4% by HPLC-UV/MS with supporting chromatogram showing clean single peak
Mass spectral identity confirmed
Mass spectrum matches expected m/z values for KPV (343.8 [M+H]+, 686.1 [2M+H]+) with CAS 67727-97-3
Batch/lot number present
Batch wgy75q7 clearly identified with Lab # 209025
Dates consistent
Sample received 7/9/2026, testing performed 7/14/2026, report issued 7/17/2026 - all dates logical and sequential
Established laboratory
Krause Analytical LLC is a known third-party testing laboratory in Austin, TX with verification URL provided
Limited testing panels
Only identity and purity panels performed. No heavy metals, microbial, endotoxin, sterility, or residual solvent testing shown on this COA
Professional presentation
Multi-page report with detailed methods summary, chromatogram, mass spectrum, and proper laboratory signatures
Potency vs label claim
8.28 mg recovered vs 10 mg label claim = 82.8% of label, which is within acceptable range for lyophilized peptides
PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.