Public COA audit

GHK-Cu

Audited July 29, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
92
Confidence
88%
Panels
2/7
Purity (printed)
99.93%

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
nhdq9dx
Identity method
HPLC-UV-MS
Sample date
2025-11-14
Issue date
2025-11-25

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

2 of 7 present · 2 passed · 0 failed · 0 reported · 5 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    ID Confirmed

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    99.93%

  • Heavy metals

    Not on this COA

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

  • Microbial

    Not on this COA

    Bioburden / microbial limits testing.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

  • Endotoxin

    Not on this COA · core

    LAL or chromogenic endotoxin assay.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

  • Sterility

    Not on this COA

    Sterility testing where applicable.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

  • Residual solvent / water

    Not on this COA

    Residual solvents or water content limits.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing

Not on this certificate. Lowers thoroughness; you decide if that panel matters for your use case. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High chromatographic purity confirmed

    99.93% purity by HPLC-UV/MS with supporting chromatogram showing clean single peak at 0.68 min

  • Identity confirmed by mass spectrometry

    Mass spectrum matches reference standard for GHK-Cu with characteristic m/z peaks at 172, 192, 342

  • Clear batch identification

    Lab # 130268, Project 135486, Sample ID nhdq9dx with product photos

  • Appropriate timeline

    Sample received 2025-11-14, tested 2025-11-19, report issued 2025-11-25 - reasonable 11-day turnaround

  • Established laboratory with verification

    Krause Analytical LLC with physical address, director signature, and verification URL provided

  • Limited testing scope

    Only identity and purity panels performed. No heavy metals, microbial, endotoxin, or sterility testing conducted. Methods summary references these tests but results not included.

  • Professional presentation

    Multi-page report with watermarks, chromatogram, mass spectra, methods summary, and proper footer attribution

  • Dual branding present

    Document shows both Finnrick.com and Krause Analytical branding, suggesting reseller/distributor relationship rather than direct lab report

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.