Public COA audit

BPC-157

Audited July 29, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
72
Confidence
83%
Panels
3/7
Purity (printed)
99.338%

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
00004
Identity method
HPLC with UV Detection Coupled with Mass Spectrometry (LCMS/MS)
Sample date
2025-11-19
Issue date
2025-11-21

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

3 of 7 present · 3 passed · 0 failed · 0 reported · 4 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    BPC-157 confirmed via mass spec [M+2H]2+ 719.23

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    99.338%

  • Heavy metals

    Not on this COA

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

  • Microbial

    Not on this COA

    Bioburden / microbial limits testing.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

  • Endotoxin

    Tested · passed · core

    LAL or chromogenic endotoxin assay.

    ≤ 0.05 EU/mL (both replicates)

  • Sterility

    Not on this COA

    Sterility testing where applicable.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

  • Residual solvent / water

    Not on this COA

    Residual solvents or water content limits.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing

Not on this certificate. Lowers thoroughness; you decide if that panel matters for your use case. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High purity confirmed

    99.338% purity by HPLC is within normal range for research-grade peptides and is supported by clean chromatogram showing single dominant peak.

  • Identity confirmed by mass spectrometry

    Mass spec data shows [M+2H]2+ ion at m/z 719.23, consistent with BPC-157. Chromatogram shows retention time labeled as BPC-157.

  • Batch/lot number present

    Lot 00004 clearly stated on both pages.

  • Dates are valid and logical

    Received 11/19/2025, Reported 11/21/2025 (2-day turnaround is reasonable). Both dates are in the past relative to today (2026-07-29).

  • Lab verification uncertain

    Freedom Diagnostics claims USA operation and provides website FreedomDiagnosticsTesting.com and email [email protected]. Independent verification of lab accreditation/credentials not possible from document alone.

  • Limited testing panels

    Only identity, purity, and endotoxin panels present. Missing heavy metals, microbial, sterility, and residual solvent/water testing. This is not uncommon for basic peptide COAs but limits comprehensive quality assurance.

  • Two separate accession numbers for same lot

    Page 1 shows accession 2511190031 (purity/identity), Page 2 shows 2511190032 (endotoxin) for the same product lot 00004. While splitting tests across accessions can occur, this creates potential confusion and is non-standard practice.

  • Professional presentation

    Document includes company branding, chromatograms, mass spec data, product photo, signatory (Stephen Schmidt, Principal Chemist), and appropriate research-use-only disclaimers.

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.