Public COA audit

BPC-157

Audited July 29, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
92
Confidence
88%
Panels
2/7
Purity (printed)
99.58%

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
129992
Identity method
HPLC-UV-MS
Sample date
2025-11-05
Issue date
2025-11-17

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

2 of 7 present · 2 passed · 0 failed · 0 reported · 5 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    ID Confirmed

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    99.58%

  • Heavy metals

    Not on this COA

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

  • Microbial

    Not on this COA

    Bioburden / microbial limits testing.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

  • Endotoxin

    Not on this COA · core

    LAL or chromogenic endotoxin assay.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

  • Sterility

    Not on this COA

    Sterility testing where applicable.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

  • Residual solvent / water

    Not on this COA

    Residual solvents or water content limits.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing

Not on this certificate. Lowers thoroughness; you decide if that panel matters for your use case. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High chromatographic purity

    99.58% purity by HPLC-UV/MS with clean chromatogram showing single dominant peak at retention time ~5.23 minutes

  • Identity confirmed by mass spectrometry

    Mass spectrum shows expected m/z 711 matching BPC-157 reference standard with good spectral overlay

  • Total peptide mass within specification

    10.6 mg measured vs 10 mg label claim (105.7% of label), within acceptable range

  • Clear batch identification

    Lab # 129992, Project 135460, sample ID bwrxnfq clearly stated

  • Appropriate timeline

    Sample received 11/5/2025, tested 11/11/2025, report issued 11/17/2025 - reasonable 12-day turnaround

  • Established laboratory

    Krause Analytical LLC is a known third-party testing laboratory in Austin, TX with verifiable address and contact information

  • Verification URL provided

    Certificate includes verification URL https://finnrick.com/verify with certificate ID bwrxnfq

  • Limited testing panels

    Only identity and purity testing performed. Methods for endotoxins and heavy metals are described on page 3 but no results are shown, suggesting these tests were not conducted for this sample

  • Professional presentation

    Multi-page report with chromatogram, mass spectrum data, methods summary, signature from Laboratory Director Mark C. Krause, and appropriate disclaimers

  • Dual branding

    Document shows both Finnrick Analytics and Krause Analytical branding, suggesting Finnrick may be a reseller/distributor using Krause as the testing lab

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.