Public COA audit

BPC 157

Audited July 28, 2026

Incomplete documentation

Missing panels or key metadata — not enough evidence to treat this as a full certificate.

Legitimacy
62
Confidence
78%
Panels
2/7
Purity (printed)
99.45%

Document details

Fields extracted from the certificate — not order or payment data.

Identity method
QTOF
Sample date
2023-08-25

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

2 of 7 present · 0 passed · 0 failed · 2 reported · 5 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · result on file · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    QTOF confirmed

  • Purity

    Tested · result on file · core

    Reported purity percentage for the analyte.

    99.45%

  • Heavy metals

    Not on this COA

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

  • Microbial

    Not on this COA

    Bioburden / microbial limits testing.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

  • Endotoxin

    Not on this COA · core

    LAL or chromogenic endotoxin assay.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

  • Sterility

    Not on this COA

    Sterility testing where applicable.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

  • Residual solvent / water

    Not on this COA

    Residual solvents or water content limits.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing

Not on this certificate. Lowers thoroughness; you decide if that panel matters for your use case. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High HPLC purity

    99.45% purity by HPLC with clear chromatogram showing dominant peak at 12.77 min and minor impurities totaling <0.6%

  • QTOF mass spec method stated

    Identity confirmation method listed as Acquity H-class Plus Xevo G2-XS QTOF, though actual mass spec data not shown on this page

  • No lot/batch number

    Lot number field shows 'N/A', which is unusual for a commercial COA and makes traceability difficult

  • No issue date

    Analysis date is provided (2023-08-25) but no separate issue/report date is shown

  • Lab identified

    Testing lab is Weipu with detailed address in Shanghai and contact information provided

  • Limited testing scope

    Only purity and identity testing shown; no heavy metals, microbial, endotoxin, sterility, or solvent/water content testing included

  • Professional presentation

    Document has clear formatting, proper chromatogram with labeled peaks, and detailed contact information

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.