Public COA audit

Wolverine · BPC-157

Audited July 28, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
95
Confidence
92%
Panels
5/7
Purity (printed)
99.84%

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
CR-BPTB20-2605-1
Identity method
HPLC-RTM (retention time matching)
Sample date
2026-05-22
Issue date
2026-06-01

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

5 of 7 present · 5 passed · 0 failed · 0 reported · 2 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    BPC-157 + TB-500 Confirmed

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    99.84%

  • Heavy metals

    Tested · passed

    Lead, arsenic, cadmium, mercury, or similar limits.

    All Not Detected (As, Cd, Cr, Hg, Pb)

  • Microbial

    Not on this COA

    Bioburden / microbial limits testing.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

  • Endotoxin

    Tested · passed · core

    LAL or chromogenic endotoxin assay.

    0.567 EU/mL

  • Sterility

    Tested · passed

    Sterility testing where applicable.

    No Growth

  • Residual solvent / water

    Not on this COA

    Residual solvents or water content limits.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing

Not on this certificate. Lowers thoroughness; you decide if that panel matters for your use case. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High purity confirmed

    99.84% purity by HPLC with conformity testing across 3 samples (mean 99.83%, std dev 0.0082%) demonstrates excellent batch consistency

  • Identity confirmed

    BPC-157 + TB-500 blend confirmed by HPLC retention time matching with reference standards

  • Batch information complete

    Lot CR-BPTB20-2605-1, COA #COA-2026-XFMMPN, Accession #ACC-2026-3096 all clearly documented

  • Timeline appropriate

    Received 2026-05-22, analyzed 2026-06-01, issued 2026-06-01 - reasonable 10-day turnaround

  • ISO/IEC 17025 accredited lab

    ILS Laboratories claims ISO/IEC 17025 accreditation with complete contact information and verification portal

  • Comprehensive testing panel

    Full QC panel includes purity, identity, heavy metals, sterility (PCR), endotoxin, and fentanyl screening

  • Missing microbial and residual solvent panels

    No traditional microbial count (CFU/TPC) or residual solvent/water content testing documented; sterility by PCR is present but does not replace quantitative microbial testing

  • Professional presentation

    Well-formatted two-page COA with chromatogram, conformity data, QR code verification, and detailed methodology notes

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.