Public COA audit

GLP-3 10mg

Audited September 5, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
88
Confidence
92%
Panels
5/7
Purity (printed)
99.69%

Scored high because the document is mostly consistent but carries soft concerns, broad panel coverage (5/7), and 1 soft concern.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
PH-re10-0526
Identity method
LC-MS
Sample date
2026-07-23
Issue date
2026-07-27

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

5 of 7 present · 5 passed · 0 failed · 0 reported · 2 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    GLP RT

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    99.69%

  • Heavy metals

    Tested · passed

    Lead, arsenic, cadmium, mercury, or similar limits.

    Pass - Arsenic, Cadmium, Lead, and Mercury below reporting/specification limits

  • Microbial

    Tested · passed

    Bioburden / microbial limits testing.

    No Detectable Microbial DNA

  • Endotoxin

    Tested · passed · core

    LAL or chromogenic endotoxin assay.

    Pass (Replicate 1 & 2, Assay Sensitivity: ≤0.05 EU/mL)

  • Sterility

    Not on this certificate file

    Sterility testing where applicable.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High purity confirmed

    HPLC-UV purity of 99.69% with supporting chromatogram showing clean single peak. Two vials tested with consistent results (99.73% and 99.64%).

  • Identity confirmed by LC-MS

    GLP retention time confirmed with mass spectrometry confirmation shown in mass spectrum graph.

  • Comprehensive testing panel

    Document includes identity, purity, heavy metals (ICP-MS), microbial (PCR), and endotoxin testing. All panels passed.

  • Established testing laboratory

    Freedom Diagnostics is a known peptide testing laboratory with website FreedomDiagnosticsTesting.com and contact email provided.

  • Recent testing dates

    Sample received 2026-07-23, reported 2026-07-27. Both dates are valid and within normal turnaround time.

  • Batch information present

    Lot number PH-re10-0526 clearly stated with accession number 2607230260.

  • Professional presentation

    Well-formatted COA with clear sections, analytical results table, chromatogram, and mass spectrum. Includes method descriptions and assay sensitivities.

  • Fentanyl screening included

    Document includes fentanyl screening (No Fentanyl Detected), which is unusual for peptide COAs but may reflect vendor quality control practices.

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.